Precautions for using brushless DC water pump (magnetic isolation pump)

Jun 13, 2025 Leave a message

1. Prevent particles from entering
(1) No ferromagnetic impurities or particles are allowed to enter the magnetic drive and bearing friction pair;
(2) After conveying media that are prone to crystallization or precipitation, it is necessary to rinse them in a timely manner (after stopping the pump, pour clean water into the pump chamber and discharge it after running for 1 minute) to ensure the service life of the sliding bearings;
(3) When conveying media containing solid particles, filtration should be carried out at the inlet of the pump flow tube.
2. Prevent demagnetization
It should operate under the specified temperature conditions, and it is strictly prohibited for the medium temperature to exceed the standard. Platinum resistance temperature sensors can be installed on the outer surface of the magnetic pump isolation sleeve to detect the temperature rise in the annular gap area, in order to alarm or shut down when the temperature exceeds the limit.
3. Prevent dry friction
Try to minimize idle time.
4. Installation below liquid level
This water pump is a centrifugal pump and cannot automatically discharge air. It must be submerged or installed below the liquid level during use.
5. Reduce idle time
Try not to idle the water pump as there is no medium lubrication during idle, which can cause wear and tear.
6. Do not exceed the rated voltage for use
It must be used at the rated voltage of the water pump, and any overpressure or other functional requirements must be specified in advance.